C 2000 basic version 2

C 2000 basic version 2

$100.00

$100.00

Add to cart
Categories:

Product Description

C 2000 basic version 2

The C 2000 basic IKA- calorimeter is a combustion calorimeter for determining gross calorific values of liquid and solid samples. A high level of automation with extremely simple handling characterizes this instrument. In addition to the isoperibolic measurement procedure (static jacket), a dynamic (reduced-time) working method is also available. To provide the calorimeter with cooling water, it needs to be connected to a thermostat f.e. IKA RC 2 basic ( accessory) or a firmly installed water connection. The C 2000 basic is equipped with a very convenient console to operate the unit.
– Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel
– Automatic oxygen filling of decomposition vessel
– Automatic decomposition vessel identification
– Automatic sample ignition
– Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
– Working methods:
isoperibol, measurement time: approx. 22 min
dynamic, measurement time: approx. 7 min
– Compact, integrated modular design for convenient operation
– Cooling water supply via thermostat f.e. IKA RC 2 basic (accessory) or firmly installed water connection (C 25 pressure regulating valve recommended)
– Interface connections for each of the following: scale, printer, monitor and sample rack C 5020
– User-friendly software C 5040 CalWin for controling the calorimeter and administration of measuring data
– Up to eight measurement cells can be controlled by a single PC, using a multi-serial plug-in card PCI 8.2 (accessory)
– LIMS integration is possible
– Special halogen resistent vessel for quantitative decomposition of halogens and sulfur
– The decomposition vessel can be changed over to use combustible crucibles C 14 ( accessory C5010.4 is needed)
– Consumables for calibrations and initial operation are included with delivery.

 

Technical Data:

Measuring range max. 40000 J
Measuring mode adiabatic 22°C no
Measuring mode isoperibol 22°C no
Measuring mode dynamic 25°C yes
Measuring mode isoperibol 25°C yes
Measuring mode dynamic 30°C yes
Measuring mode isoperibol 30°C yes
Measuring mode double dry (ISO 1928) no
Measuring time dynamic approx. 7 min
Measuring time isoperibol approx. 22 min
Reproducibility dynamic (1g benzoic acid NBS39i) 0.1 %RSD
Reproducibility isoperibol (1g benzoic acid NBS39i) 0.05 %RSD
Working temperature max. 30 °C
Temperature measurement resolution 0.0001 K
Cooling medium temperature min. 12 °C
Cooling medium temperature max. 28 °C
Cooling medium permissible operating pressure 1.5 bar
Cooling medium tap water
Type of cooling flow
Flow rate min. 0.3 l/h
Flow rate max. 70 l/h
Oxygen operating pressure max. 40 bar
Interface scale RS232
Interface printer Centronix
Interface PC RS232
Interface test rack yes
Interface ext. monitor yes
Interface ext. keyboard yes
Oxygen filling yes
Degasification no
Decomposition detection yes
Decomposition vessel C 5010 no
Decomposition vessel C 5012 yes
Decomposition vessel C 7010 no
Decomposition vessel C 7012 no
Decomposition vessel C 62 no
Analysis according to DIN 51900 yes
Analysis according to ASTM D240 yes
Analysis according to ASTM D4809 yes
Analysis according to ASTM D1989 yes
Analysis according to ASTM D5468 yes
Analysis according to ASTM D5865 yes
Analysis according to ASTM E711 yes
Dimensions (W x H x D) 440 x 500 x 450 mm
Weight 30 kg
Permissible ambient temperature 20 – 25 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 21
RS 232 interface yes
Voltage 220 – 240 V
Frequency 50/60 Hz
Power input 1800 W
Back to top