C 2000 basic version 2
$100.00
Product Description
C 2000 basic version 2
The C 2000 basic IKA- calorimeter is a combustion calorimeter for determining gross calorific values of liquid and solid samples. A high level of automation with extremely simple handling characterizes this instrument. In addition to the isoperibolic measurement procedure (static jacket), a dynamic (reduced-time) working method is also available. To provide the calorimeter with cooling water, it needs to be connected to a thermostat f.e. IKA RC 2 basic ( accessory) or a firmly installed water connection. The C 2000 basic is equipped with a very convenient console to operate the unit.
– Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel
– Automatic oxygen filling of decomposition vessel
– Automatic decomposition vessel identification
– Automatic sample ignition
– Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
– Working methods:
isoperibol, measurement time: approx. 22 min
dynamic, measurement time: approx. 7 min
– Compact, integrated modular design for convenient operation
– Cooling water supply via thermostat f.e. IKA RC 2 basic (accessory) or firmly installed water connection (C 25 pressure regulating valve recommended)
– Interface connections for each of the following: scale, printer, monitor and sample rack C 5020
– User-friendly software C 5040 CalWin for controling the calorimeter and administration of measuring data
– Up to eight measurement cells can be controlled by a single PC, using a multi-serial plug-in card PCI 8.2 (accessory)
– LIMS integration is possible
– Special halogen resistent vessel for quantitative decomposition of halogens and sulfur
– The decomposition vessel can be changed over to use combustible crucibles C 14 ( accessory C5010.4 is needed)
– Consumables for calibrations and initial operation are included with delivery.
Technical Data:
Measuring range max. | 40000 J |
Measuring mode adiabatic 22°C | no |
Measuring mode isoperibol 22°C | no |
Measuring mode dynamic 25°C | yes |
Measuring mode isoperibol 25°C | yes |
Measuring mode dynamic 30°C | yes |
Measuring mode isoperibol 30°C | yes |
Measuring mode double dry (ISO 1928) | no |
Measuring time dynamic approx. | 7 min |
Measuring time isoperibol approx. | 22 min |
Reproducibility dynamic (1g benzoic acid NBS39i) | 0.1 %RSD |
Reproducibility isoperibol (1g benzoic acid NBS39i) | 0.05 %RSD |
Working temperature max. | 30 °C |
Temperature measurement resolution | 0.0001 K |
Cooling medium temperature min. | 12 °C |
Cooling medium temperature max. | 28 °C |
Cooling medium permissible operating pressure | 1.5 bar |
Cooling medium | tap water |
Type of cooling | flow |
Flow rate min. | 0.3 l/h |
Flow rate max. | 70 l/h |
Oxygen operating pressure max. | 40 bar |
Interface scale | RS232 |
Interface printer | Centronix |
Interface PC | RS232 |
Interface test rack | yes |
Interface ext. monitor | yes |
Interface ext. keyboard | yes |
Oxygen filling | yes |
Degasification | no |
Decomposition detection | yes |
Decomposition vessel C 5010 | no |
Decomposition vessel C 5012 | yes |
Decomposition vessel C 7010 | no |
Decomposition vessel C 7012 | no |
Decomposition vessel C 62 | no |
Analysis according to DIN 51900 | yes |
Analysis according to ASTM D240 | yes |
Analysis according to ASTM D4809 | yes |
Analysis according to ASTM D1989 | yes |
Analysis according to ASTM D5468 | yes |
Analysis according to ASTM D5865 | yes |
Analysis according to ASTM E711 | yes |
Dimensions (W x H x D) | 440 x 500 x 450 mm |
Weight | 30 kg |
Permissible ambient temperature | 20 – 25 °C |
Permissible relative humidity | 80 % |
Protection class according to DIN EN 60529 | IP 21 |
RS 232 interface | yes |
Voltage | 220 – 240 V |
Frequency | 50/60 Hz |
Power input | 1800 W |