The HI5221 is an advanced research grade benchtop pH/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5221 is rich in features including five-point calibration, selectable resolution, data logging, alarm limits, comprehensive GLP, and much more. This meter retains simplicity with both dedicated keys for routine operation and virtual keys that guide the user through setup options.
The HI5221 ensures confidence in measurements with the exclusive Hanna Instruments CAL Check™ feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.
Add to cart
Product Description
HANNA – HI5221
Laboratory Research Grade Benchtop pH/mV Meter with 0.001 pH Resolution
pH SPECIFICATIONS:-
pH Range | -2.0 to 20.0 pH, -2.00 to 20.00 pH, -2.000 to 20.000 pH |
pH Resolution | 0.1, 0.01, 0.001 pH |
pH Accuracy (@25ºC/77ºF) | ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD |
pH Calibration | automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45) and five custom buffers |
pH Temperature Compensation | automatic or manual from -20.0 to 120.0 °C |
mV Range | ±2000 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.2 mV ±1 LSD |
Relative mV Offset Range | ±2000 m |
TEMPERATURE SPECIFICATIONS:-
Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F, 253.15 to 393.15 K |
Temperature Resolution | 0.1 °C, 0.1 °F, 0.1 K |
Temperature Accuracy | ±0.2 °C, ±0.4 °F, ±0.2 K |
ADDITIONAL SPECIFICATIONS:-
Electrode/Probe | HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included) |
Temperature Probe | HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) |
GLP | calibration data including date, time, buffers used, offset and slope |
Logging | record: 100,000 data point storage, 100 lots with 50,000 records/lot; interval: settable between 1 second and 180 minutes max log time; type: automatic, manual, AutoHold |
Input Channels | 1 – pH/ORP |
Display | color graphic LCD with on-screen help, graphing, and custom color configuration |
Connectivity | USB |
Environment | 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing |
Power Supply | 12 VDC adapter (included) |
Dimensions | 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) |
Weight | 1.2 kg (2.64 lbs.) |
Ordering Information | HI5221 is supplied with HI1131B pH electrode, HI7662-T temperature probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC adapter and instructions. |