HI2550

HI2550

$100.00

HANNA – HI2550

Multiparameter pH/mV/ISE and EC/TDS/Salinity Benchtop Meter

The HI2550 is a rugged and highly accurate multiparameter benchtop meter. Offering two input channels, this meter is able to measure up to seven parameters including pH, ORP, ISE, EC, TDS, salinity, and temperature. The meter comes with Hanna’s HI1131B glass pH electrode, HI76310 four-ring conductivity probe, and a temperature probe to allow for automatic temperature compensation. The HI2550 offers many features including five-point pH calibration, auto ranging EC and TDS measurements, data logging, comprehensive GLP data, and PC connectivity via USB to provide users with a simple way to organize and manage their data.

$100.00

Add to cart

Product Description

HANNA – HI2550

Multiparameter pH/mV/ISE and EC/TDS/Salinity Benchtop Meter

pH Specifications

pH Range –2.0 to 16.0 pH, -2.000 to 16.000 pH, -2.00 to 16.00 pH
pH Resolution 0.1, 0.01, 0.001 pH
pH Accuracy (@25ºC/77ºF) ±0.01 pH, ±0.002 pH
pH Calibration up to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and two custom buffers
pH Temperature Compensation automatic or manual from -20.0 to 120.0 °C
Relative mV Offset Range ±2000 mV

EC Specifications

EC Range up to 500.0 mS/cm actual* conductivity, 0.00 to 29.99 µS/cm, 30.0 to 299.9 µS/cm, 300 to 2999 µS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm
EC Resolution 0.01 µS/cm, 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy (@25ºC/77ºF) ±1% of reading (±0.05 µS/cm or 1 digit, whichever is greater)
EC Calibration one point slope calibration; six buffers available: 84.0, 1413 µS/cm; 5.00, 12.88, 80.0, 111.8 mS/cm; one point offset: 0.00 µS/cm
EC Temperature Compensation automatic or manual from -20.0 to 120.0°C, or disabled

TDS Specifications

TDS Range up to 400.0 g/L actual* TDS (with 0.80 factor), 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy (@25ºC/77ºF) ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Factor 0.40 to 0.80 (default value is 0.50)

Salinity Specifications

Salinity Range 0.0 to 400.0% NaCl
Salinity Resolution 0.1% NaCl
Salinity Accuracy (@25ºC/77ºF) ±1% of reading (excluding probe error)
Salinity Calibration one point, with HI7037 calibration solution (optional)

Temperature Specifications

Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Accuracy ±0.4°C (±0.8°F) (excluding probe error)
Temperature Resolution 0.1°C (0.1°F)
Temperature Coefficient 0.00 to 6.00 %/°C (for EC and TDS only; default value is 1.90 %/°C

ISE Specifications

ISE/ORP Range ±999.9 mV; ±2000 mV
ISE/ORP Resolution 0.1 mV (±1000.0 mV); 1 mV (± 2000 mV)
ISE/ORP Accuracy ± 0.2 mV (±999.9 mV); ± 1 mV (±2000 mV)

Additional Specifications

pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
EC Probe HI76310 platinum four-ring EC/TDS probe and 1 m (3.3’) cable (included)
Temperature Probe HI7662 temperature probe, stainless steel with 1 m (3.3’) cable (included)
Logging 200 samples, log-on-demand
Logging Interval 500 records; 5, 10, 30 sec and 1, 2, 5, 10, 15, 30, 60, 120, 180 min stability logging
Connectivity opto-isolated USB
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Input Impedance 10¹² Ohms
Power Supply 12 VDC adapter (included)
Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)
Weight 1.3 kg (2.9 lb); kit with holder 2.1 kg (4.6 lb)
Ordering Information HI2550 is supplied with HI1131B pH electrode, HI76310 EC/TDS probe, HI7662 temperature probe, HI76404N electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI7071 Electrolyte Fill Solution, 3.5M KCl + AgCl (30 mL), 12 VDC adapter and instruction manual.
Back to top