C 5000 control package 2/12

C 5000 control package 2/12

$100.00

$100.00

Add to cart
Categories:

Product Description

C 5000 control package 2/12

The IKA® calorimeter C 5000 control is the only calorimeter in the world that offers a free selection of 3 working methods:
Thus it is possible to perform determinations of gross calorific values of liquid and solid samples in adiabatic (approx. 14 – 18 min), isoperibolic (approx. 22 min) and dynamic (reduced time: approx. 10 min) mode. A high level of automation in addition to an extensive range of accessories leave nothing more to wish for.
– Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel
– Automatic oxygen filling and degassing of the decomposition vessel
– Automatic decomposition vessel identification
– Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
– Interface connections for each of the following: scale, printer, monitor and sample rack C 5020
– User-friendly software C 5040 CalWin for controlling the calorimeter and administration of measuring data (accessory)
– LIMS integration is possible
– Cooling water supply via thermostat f.e IKA KV 600 ( accessory ) or firmly installed water connection, (temperature range 10 – 19 °C)
– Special halogen resistent vessel C 5012 for quantitative decomposition of halogens and sulfur
– The decomposition vessel can be changed over to use combustible crucibles C 14 ( accessory C 5010.4 is needed )
– Standard consumables for calibrations and initial operation included with delivery

 

Technical Data:

Measuring range max. 40000 J
Measuring mode adiabatic 22°C On Request
Measuring mode dynamic 22°C On Request
Measuring mode isoperibol 22°C On Request
Measuring mode adiabatic 25°C yes
Measuring mode dynamic 25°C yes
Measuring mode isoperibol 25°C yes
Measuring mode dynamic 30°C no
Measuring mode isoperibol 30°C no
Measuring mode double dry (ISO 1928) no
Measuring time adiabatic approx. 15 min
Measuring time dynamic approx. 10 min
Measuring time isoperibol approx. 22 min
Reproducibility adiabatic (1g benzoic acid NBS39i) 0.05 %RSD
Reproducibility dynamic (1g benzoic acid NBS39i) 0.1 %RSD
Reproducibility isoperibol (1g benzoic acid NBS39i) 0.05 %RSD
Working temperature max. 25 °C
Temperature measurement resolution 0.0001 K
Cooling medium temperature min. 10 °C
Cooling medium temperature max. 19 °C
Cooling medium permissible operating pressure 9 bar
Cooling medium tap water
Type of cooling flow
Flow rate min. 18 l/h
Flow rate max. 42 l/h
Rec. flow rate at 18°C 40 l/h
Oxygen operating pressure max. 40 bar
Interface scale RS232
Interface printer Centronix
Interface PC RS232
Interface test rack yes
Interface ext. monitor no
Interface ext. keyboard no
Oxygen filling yes
Degasification yes
Decomposition detection yes
Decomposition vessel C 5010 yes
Analysis according to DIN 51900 yes
Analysis according to ASTM D240 yes
Analysis according to ASTM D4809 yes
Analysis according to ASTM D1989 yes
Analysis according to ASTM D5468 yes
Analysis according to ASTM D5865 yes
Analysis according to ASTM E711 yes
Dimensions (W x H x D) 560 x 400 x 380 mm
Weight 42 kg
Permissible ambient temperature 20 – 25 °C
Permissible relative humidity 80 %
Protection class according to DIN EN 60529 IP 21
RS 232 interface yes
Voltage 230 V
Frequency 50/60 Hz
Power input 1300 W
Back to top