HI3512

HI3512

$100.00

HANNA – HI3512

Professional Multiparameter Benchtop pH/mV/ISE and EC/TDS/Resistivity/Salinity Meter

The HI3512 is a professional, accurate multiparameter benchtop meter. Offering two input channels, this meter is able to measure up to eight parameters including pH, ORP, ISE, EC, TDS, resistivity, salinity, and temperature. The meter comes with Hanna’s HI1131B glass pH electrode, HI76310 four-ring conductivity probe, and a temperature probe to allow for automatic temperature compensation. The HI3512 offers many features including CAL Check, five-point pH and ISE calibration, autoranging EC, TDS, and resistivity measurements, data logging, comprehensive GLP data, and PC connectivity via USB to provide users with a simple way to organize and manage their data.

$100.00

Add to cart

Product Description

HANNA – HI3512

Professional Multiparameter Benchtop pH/mV/ISE and EC/TDS/Resistivity/Salinity Meter

pH Specifications

pH Range -2.0 to 20.0 pH, -2.00 to 20.00 pH, -2.000 to 20.000 pH
pH Resolution 0.1, 0.01, 0.001 pH
pH Accuracy (@25ºC/77ºF) ±0.01 pH, ±0.002 pH
pH Calibration up to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and two custom buffers
pH Temperature Compensation automatic or manual from -20.0 to 120.0 °C
mV Range ±2000 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV
Relative mV Offset Range ±2000 mV

EC Specifications

EC Range 0 µS/cm to 400 mS/cm (shows values up to 1000 mS/cm absolute conductivity), 0.001 to 9.999 µS/cm, 10.00 to 99.99 µS/cm, 100.0 to 999.9 µS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 1000 mS/cm (autoranging)
EC Resolution 0.001 µS/cm, 0.01 µS/cm, 0.1 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm
EC Accuracy (@25ºC/77ºF) ±1% of reading (±0.01 µS/cm or 1 digit whichever is greater) excluding probe error
EC Calibration automatic up to two points with seven Hanna standards (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
EC Temperature Compensation NoTC, MTC, ATC

TDS Specifications

TDS Range 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 g/L, 10.00 to 99.99 g/L, 100.0 to 400.0 g/L (autoranging)
TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L, 0.001 g/L
TDS Accuracy (@25ºC/77ºF) ±1% of reading (±0.05 ppm or 1 digit whichever greater) excluding probe error
TDS Factor 0.40 to 1.00

Resistivity Specifications

Resistivity Range 1.0 to 99.9 O•cm; 100 to 999 KO•cm; 1.00 to 9.99 KO•cm; 10.0 to 99.9 KO•cm; 100 to 999 KO•cm; 1.00 to 9.99 MO•cm; 10.0 to 100.0 MO•cm (autoranging)
Resistivity Resolution 0.1 O•cm; 1 O•cm; 0.01 KO•cm; 0.1 KO•cm; 1 KO•cm; 0.01 MO•cm; 0.1 MO•cm
Resistivity Accuracy ±1% of reading (±10 O or 1 digit whichever greater) excluding probe error

Salinity Specifications

Salinity Range 0.0 to 400.0% NaCl
Salinity Resolution 0.1% NaCl
Salinity Accuracy (@25ºC/77ºF) ±1% of reading (excluding probe error)
Salinity Calibration one point, with HI7037 calibration solution (optional)

Temperature Specifications

Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Accuracy ±0.2°C; ±0.4°F (excluding probe error)
Temperature Resolution 0.1°C (0.1°F)
Temperature Coefficient 0.00 to 10.00 %/°C (for EC and TDS only; default value is 1.90%/°C)
Reference Temperature 15°C, 20°C and 25°C

ISE Specifications

ISE Range 1.00 E-7 to 9.99 E10 concentration (user selectable units)
ISE Resolution 3 digits
ISE Accuracy @ 25 °C/77 °F ±0.5% (monovalent ions); ±1% (divalent ions)
ISE Calibration Points up to five-point calibration points six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm)

Additional Specifications

Cell Constant 0.010 to 10.000
pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
EC Probe HI76310 platinum four-ring EC/TDS probe and 1 m (3.3’) cable (included)
Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)
Slope Calibration from 80 to 110%
Temperature Source automatic from sensor inside the probe; manual entry
Logging 400 samples, log-on-demand
Logging Interval 5, 10, 30 seconds; 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes, AutoEnd (max 600 samples)
Connectivity opto-isolated USB
Environment 0 to 50°C (32 to 122°F), RH max 55% non-condensing
Input Impedance 10¹² Ohms
Power Supply 12 VDC adapter (included)
Dimensions 235 x 207 x 110 mm (9.2 x 8.14 x 4.33”)
Weight 1.8 kg (4 lbs)
Ordering Information HI3512 is supplied with HI76310 EC/TDS probe, HI1131B pH electrode, HI7662-T temperature probe, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), HI76404N electrode holder, 12 VDC adapter and instructions.
Back to top