HI5222

HI5222

$100.00

HANNA – HI5222

Research Grade pH/ISE/ORP Meter with CAL Check™

The HI5222 is an advanced research grade dual channel benchtop pH/ISE/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5222 is rich in features including 5 point calibration, selectable resolution, data logging, alarm limits, comprehensive GLP, and many more while retaining simplicity in use with both dedicated key for routine operation and virtual keys that guide the user through setup options. The HI5522 ensures confidence in measurements with the exclusive Hanna Instruments CAL Check feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.

$100.00

Add to cart

Product Description

HANNA – HI5222

Research Grade pH/ISE/ORP Meter with CAL Check™

pH SPECIFICATIONS:-

pH Range -2.000 to 20.000 pH
pH Resolution 0.1, 0.01, 0.001 pH
pH Accuracy (@25ºC/77ºF) ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD
pH Calibration automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45) and five custom buffers
pH Temperature Compensation automatic or manual from -20.0 to 120.0 °C
mV Range ±2000 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV ±1 LSD
Relative mV Offset Range ±2000 mV

TEMPERATURE SPECIFICATIONS:-

Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F, 253.15 to 393.15 K
Temperature Resolution 0.1 °C, 0.1 °F, 0.1 K
Temperature Accuracy ±0.2 °C, ±0.4 °F, ±0.2 K

 

ISE SPECIFICATIONS:-

ISE Range 1 x 10?6 to 9.99 x 10?° concentration
ISE Resolution 1; 0.1; 0.01; 0.001 concentration
ISE Accuracy @ 25 °C/77 °F ±0.5% (monovalent ions); ±1% (divalent ions)
ISE Calibration Points automatic, up to five point calibration, five fixed standard solutions available (0.1, 1, 10, 100, 1000 choice of concentration) and five user defined units

 

ADDITIONAL SPECIFICATIONS:-

Electrode/Probe HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)
GLP calibration data including date, time, buffers used, offset and slope
Logging record: 100,000 data point storage, 100 lots with 50,000 records/lot; interval: settable between 1 second and 180 minutes max log time; type: automatic, manual, AutoHold
Input Channels 2 – pH/ORP/ISE
Display color graphic LCD with on-screen help, graphing, and custom color configuration
Connectivity USB
Environment 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing
Power Supply 12 VDC adapter (included)
Dimensions 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)
Weight 1.2 kg (2.64 lbs.)
Ordering Information HI5222 is supplied with HI1131B pH electrode, HI7662-T temperature probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC adapter and instructions.
Back to top