HI83414

HI83414

$100.00

HANNA -HI 83414

Turbidity and Free/Total Chlorine Benchtop Meter, EPA Complian

The HI83414 is a high accuracy Turbidity and Chlorine Benchtop Meter. This meter is a combination of a nephelometer and photometer to measure the most important parameters in drinking water: turbidity and chlorine. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards and NIST traceable secondary chlorine standards used for calibration and performance verification. The HI83414 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.The chlorine measurements are are adapted EPA Method 330.5 and Standard Method 4500-Cl G.

Compliant to EPA Methods

Up to ±0.02 NTU accuracy

USB for data transfer

$100.00

Add to cart

Product Description

HANNA -HI 83414

Turbidity and Free/Total Chlorine Benchtop Meter, EPA Complian

GENERAL SPECIFICATION :-

Light Source tungsten filament lamp / greater than 100,000 readings
Display 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
Log Memory 200 records
Connectivity USB
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Power Supply 115/130 VAC; 50/60 Hz
Dimensions 230 x 200 x 145 mm (9.0 x 7.9 x 5.7”)
Weight 2.5 kg (88 oz.)
Ordering Information HI83414 is supplied with sample cuvettes (5) with caps, HI88703-11 calibration cuvettes for turbidity, HI93414-11 calibration cuvettes for chlorine, silicone oil, cuvette wiping cloth, scissors, power cord, and instruction manual.

 

TURBIDITY SPECIFICATION:-

Non-Ratio Mode Range 0.00 to 9.99; 10.0 to 40.0 NTU; 0.0 to 99.9; 100 to 268 Nephelos; 0.00 to 9.80 EBC
Non-Ratio Mode Resolution 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC
Ratio Mode Range 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU; 0.0 to 99.9; 100 to 26800 Nephelos; 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
Ratio Mode Resolution 0.01; 0.1; 1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC
Range Selection automatic
Accuracy ±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC); ±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC)
Repeatability ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater
Stray Light < 0.02 NTU (0.15 Nephelos; 0.01 EBC)
Light Detector silicon photocell
Method nephelometric method (90°) or ratio nephelometric method (90° & 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Measuring Mode normal, average, continuous
Turbidity Standards < 0.1, 15, 100, 750 and 2000 NTU
Calibration two, three, four, or five-point calibration

 

FREE AND TOTAL CHLORINE SPECIFICATION:-

Free and Total Chlorine Range 0.00 to 5.00 mg/L (ppm)
Free and Total Chlorine Resolution 0.01 mg/L (ppm) from 0.00 to 3.50 mg/L (ppm); 0.10 above 3.50 mg/L (ppm)
Free and Total Chlorine Accuracy ±0.02 mg/L @ 1.00 mg/L
Light Detector silicon photocell with 525 nm narrow band interference filter
Method adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G.
Standards 1.00 mg/L (ppm) free chlorine; 1.00 mg/L (ppm) total chlorine
Calibration one-point calibration

 

Back to top